Contact Me

Rafael Moreno

Mail: moreno@energielink.ch

Phone: +41 76 512 47 73

Dampers for steelworks

These are dampers that are specially designed and manufactured for use under the demanding operating conditions found in smelters and steel mills.

We provide designs tailored to the particular application to deal with the generally high volumes of furnace gas, process air and exhaust gas encountered.  Multi-vane dampers connected via a rod are mainly used in steelworks. This ensures the vanes move in harmony.

Sealing variants of valves and dampers for steelworks

Our product portfolio includes butterfly and double shut-off dampers with sealing air for 100% tightness and throttle dampers for optimum control. These are mainly metal sealing (e.g. with spring plates), but also soft sealing. Fans and heating registers for the sealing air are also provided, depending on requirements. We supply an optimally tailored solution in every case.

Special requirements for the steel industry

In steelworks in particular, a minimum leakage volume needs to be maintained at times. This means that the damper should not be tight, but must exhibit a minimum leakage of, for example, 2%. In addition, particular attention must be paid to dust content, high temperatures still prevailing in some cases and corrosive gases in the steel industry. In addition to coated solutions, we provide steel and stainless-steel dampers for this purpose.

Electric or pneumatic actuators and manually operated gears can be used as drives.

Image

A product line from EnergieLink

Furnace gas

Design

  • round or angular
  • robust design
  • low maintenance
  • single or multi-vane

Size

  • depending on requirement

Tightness

  • 99 %-99.9 % area equivalent
  • up to 100 % tightness with sealing air

Temperature

  • up to 600°C

Drives

  • electric rotary drive
  • pneumatic actuator
  • manual with hand wheel/lever

Process air

Design

  • round or angular
  • robust design
  • low maintenance
  • multi-vane

Size

  • depending on requirement

Tightness

  • 97 %-99 % area equivalent

Temperature

  • up to 1400°C

Drives

  • electric variable speed drive
  • pneumatic actuator with control

Gas purification

Design

  • round or angular
  • robust design
  • low maintenance
  • single or multi-vane

Size

  • depending on requirement

Tightness

  • 99 %-99.9 % area equivalent
  • up to 100 % tightness with sealing air

Temperature

  • up to 600°C

Drives

  • electric rotary drive
  • pneumatic actuator
  • manual with hand wheel/lever

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.